This Demister fist the Premier Oil Pump used in Harvest Right home freeze dryers.

The Harvest Right Oil Pump Demister keeps your oil pump clean and efficient by separating oil from the air, ensuring that the air released from your pump is free from the build up of oil mist, which can help prolong the life of your equipment and maintain optimal performance.

Features

• User-Friendly Design: With a simple dial operation, sealing your food has never been easier. Just place the bag in the machine, set the dial to the appropriate level (based on thickness of your bag), and let the sealer do the work!

• Durable Construction: Built to last, this sealer features high-quality materials that can withstand regular use while delivering consistent results.

• Compact and Portable: Its sleek, space-saving design means it fits easily on any countertop or can be stored away when not in use.

• 12" Sealing Width: Accommodates a variety of bag sizes, making it perfect for sealing everything from snacks to bulk purchases.

What's Included

• Harvest Right 12" Impulse Sealer

How to Use

What the demister does:
- Captures oil mist from the vacuum pump exhaust
- Keeps oil from coating your room, walls, or freeze dryer
- Reduces odor and mess during long runs

What you need
- Harvest Right demister (assembled)
- Paper towel or small container (for first test run)
- Ensure your vacuum pump is turned OFF:

Installation (most important part)

1. Turn off and unplug the pump Never install while the pump is running.
2. Locate the exhaust port. On Harvest Right pumps, this is the top port (not the vacuum hose port).
3. Remove the exhaust cap or plug. Some pumps ship with a plastic cap—remove it.
4. Thread the demister onto the exhaust
5. Hand-tighten only (snug, not forced).
6. Keep it vertical so oil can drain properly.
7. Check the drain port. Some demisters have a drain screw or hose at the bottom. Make sure it’s closed before operation.
8. First use / test run
9. Run the pump for 5–10 minutes. No freeze dryer needed for this test.
10. Check for oil mist
11. You should see little to no vapor coming out the top.
12. A very light airflow is normal.
13. Check for leaks
14. If oil appears around the threads, shut off and reseat the demister.

During normal operation
- Leave the demister installed at all times
- Expect Quiet airflow, no oil spray or strong oil smell

Maintenance & cleaning after every few batches:
- Wipe the outside
- Check that airflow is not restricted
- Periodically (or if airflow drops)
- Unscrew the demister
- Open the housing
- Clean or replace the filter media (depending on model)
- Empty any collected oil
- Reassemble and reinstall

👉 If oil accumulates inside, you can pour it back into the pump (filtered through a paper towel).

Common mistakes to avoid

❌ Installing it on the vacuum hose port (wrong port)
❌ Over-tightening
❌ Running the pump without oil (demister doesn’t replace oil checks)
❌ Letting the demister tip sideways

Tips for best results:
- Keep pump oil clean and at proper level
- Use in a well-ventilated area
- If you still smell oil → clean or replace the demister filter